Tankless water heater sizing comes down to two numbers: how much hot water you need at once (flow rate, in gallons per minute) and how much the unit has to raise the temperature of your incoming water (temperature rise). Get those two right and a tankless heater keeps up with your household. Get them wrong and the second shower runs lukewarm.
This guide walks through the math the same way a plumber would, explains where Atlanta homes tend to run into trouble, and shows what we check before recommending a unit.
How Tankless Water Heaters Are Rated
A tank heater is sized by how many gallons it stores. A tankless heater stores almost nothing, so it is rated by how much water it can heat at a given temperature rise. The U.S. Department of Energy describes demand-type heaters as “rated by the maximum temperature rise possible at a given flow rate.” For example, DOE notes that gas-fired units are typically rated for a 70°F rise at about 5 gallons per minute, while electric units are typically rated for the same rise at about 2 gallons per minute.
That difference is why fuel type matters so much for whole-house sizing. Electric units are often a good fit for a single bathroom or a point-of-use job, while a whole house usually points to gas. It is also why the answer to “what size do I need” is never just a number of bedrooms.
Step 1: Add Up the Fixtures That Run at the Same Time
Start with the busiest realistic moment in your house, not every fixture you own. A morning with one shower and a running bathroom sink is a different load than two showers plus a dishwasher.
The flow rates below are federal and EPA figures. Your actual fixtures may differ, so check the label or measure them.
| Fixture | Typical Flow Rate | Source |
|---|---|---|
| Standard showerhead | 2.5 GPM | EPA WaterSense |
| WaterSense showerhead | 2.0 GPM or less | EPA WaterSense |
| Bathroom sink faucet, WaterSense | 1.5 GPM or less | EPA WaterSense |
| Bathroom sink faucet, federal maximum | 2.2 GPM | 10 CFR Part 430, cited by EPA |
You can measure a fixture yourself by holding a bucket under it for one minute and measuring the water collected. DOE suggests the same method. Showers and faucets also mix hot water with cold, so the heater usually supplies less than the full fixture flow, but sizing to the full number gives you a safety margin.
DOE’s own example adds a 0.75 GPM faucet and a 2.5 GPM shower, which gives a required flow of at least 3.25 GPM through the heater. Two showers at 2.5 GPM each, running together, would call for about 5 GPM.
Step 2: Work Out the Temperature Rise
Temperature rise is the difference between the temperature of the water coming into the house and the temperature you want at the heater. DOE says most uses call for 120°F, and that if you do not know your incoming temperature you can assume 50°F. That gives a 70°F rise.
Incoming water is colder in winter, which means a larger rise and less flow from the same unit. We have not verified a measured winter inlet temperature for metro Atlanta, so we do not quote one here. Your installer should measure it or use the manufacturer’s regional guidance. Rinnai, for example, publishes a ground water temperature map and a sizing table that pairs inlet temperature bands with maximum flow rates, and it notes that actual inlet temperature can vary locally and by season.
A hypothetical example: if the water entering your home is 45°F in January and you want 120°F, the rise is 75°F. A unit that comfortably delivers 5 GPM at a 70°F rise will deliver somewhat less at 75°F.
Step 3: Match the Numbers to a Unit
Now compare your peak flow and temperature rise against the manufacturer’s flow table for the model you are considering. Every manufacturer publishes one. If your household needs 5 GPM at a 70°F rise, you want a unit that delivers at least that at your coldest inlet temperature, not just on a mild day.
For gas units, you can also estimate the heat the unit has to produce. Heating water takes roughly 500 BTU per hour for each gallon per minute for each degree of rise. A 5 GPM load at a 70°F rise works out to about 175,000 BTU per hour of heat delivered to the water. The unit’s gas input has to be a bit higher than that, because no heater is 100 percent efficient. Use the manufacturer’s rated input and efficiency rather than our shortcut when you choose a model.
Is Bigger Always Better?
No. An oversized unit costs more, draws more gas, and needs a larger gas supply. It also may not help if your real limit is somewhere else, such as the gas line, the vent, or the water pressure in the house.
Undersized is the more common complaint. If two people shower at once and the water turns cold, the heater is usually being asked for more flow than it can heat. Low-flow fixtures help, and in some homes a second unit or a recirculation setup is the better answer than one very large heater.
What Atlanta Homes Add to the Equation
Gas Line Capacity
A gas tankless heater draws far more gas at once than a tank heater. The Department of Energy’s Building America guide notes that a gas-fired tankless unit can add 175,000 BTU per hour or more to a home’s gas load, that the in-house gas line serving it will in most cases need to be three-quarter inch, and that in a retrofit the line serving the house may need to be enlarged.
That matters in older intown neighborhoods. Homes built when the gas line only had to serve a furnace and a tank heater can need a larger line before a whole-house tankless unit will perform as rated. We check the gas line and meter capacity during the site visit rather than guessing. Our tankless installation cost guide covers how a gas line upgrade changes the price.
Venting and Condensate
Gas-fired tankless heaters must be vented according to local codes and the manufacturer’s instructions, and condensing models also need a condensate drain. In an existing home, routing a new vent through finished walls is often the most disruptive part of the job. It is worth asking about before you fall in love with a particular model.
Permits and Inspections
Changing a water heater to tankless often involves the gas line, venting, or electrical work, which is the kind of work that usually triggers a permit. We explain the details in our guide to permits for tankless water heater installation in Georgia. Confirm current requirements with the City of Atlanta or your county before any work begins.
Quick Sizing Guidance by Household
These are starting points for a conversation, not a specification. Real sizing depends on your fixtures, your incoming water temperature, and the fuel and gas supply available.
- Light use, one bathroom, one person at a time: often a candidate for a smaller gas unit, or an electric unit if the electrical service can support it.
- Family of four, two bathrooms: usually calls for a gas unit sized for at least two fixtures running together, with low-flow fixtures making a real difference.
- Large household, three or more bathrooms, or a soaking tub: may need a larger unit, two units, or a recirculation loop, and gas line capacity becomes the first thing to check.
What We Look at Before We Recommend a Unit
On a Fix & Flow tankless visit, we confirm the fixtures that will run together, the incoming water temperature, the existing gas line and meter, the vent path, and where the condensate and relief lines can go. That is also the standard work on installs like our Gresham Park tankless installation, where we replaced the tank, upgraded exposed CPVC to rigid copper, and installed the relief and condensate lines and a properly vented intake and exhaust.
Replacing a tank is not always the right call. If a hybrid unit fits your situation better, our hybrid water heater page explains when that makes sense.
Get a Sizing Check Before You Buy
If you are weighing a tankless upgrade, a short site visit will tell you more than any calculator. See our tankless water heater installation and repair service for what we do, or contact Fix & Flow or call 404-800-3569 to schedule an assessment.